Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Users
  • Groups
Skins
  • Light
  • Brite
  • Cerulean
  • Cosmo
  • Flatly
  • Journal
  • Litera
  • Lumen
  • Lux
  • Materia
  • Minty
  • Morph
  • Pulse
  • Sandstone
  • Simplex
  • Sketchy
  • Spacelab
  • United
  • Yeti
  • Zephyr
  • Dark
  • Cyborg
  • Darkly
  • Quartz
  • Slate
  • Solar
  • Superhero
  • Vapor

  • Default (No Skin)
  • No Skin
Collapse
WIBIMMERS logo

WIBIMMERS

  1. Home
  2. General Discussion
  3. Members BMWs
  4. Non-BMW Stuff on a BMW Forum

Non-BMW Stuff on a BMW Forum

Scheduled Pinned Locked Moved Members BMWs
1.2k Posts 29 Posters 0 Views 1 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • G
    G
    gilber33
    wrote on last edited by
    #711

    That is extremely helpful! Thank you for all of that information.

    1 Reply Last reply
    1
    • G
      G
      gilber33
      wrote on last edited by
      #712

      These gauges took way more work and time than I thought they would. Mostly because the bracket fit like garbage once the two screws on the back of it were tightened down.

      In the end I had to get out the belt sander and shave one side down so it fit in the cubby. Out of the box it was maybe 1/16” too wide making the fit very poor. It would fit OK when it was loosely sitting in there, but once tightened down it would lift up towards the front. I basically bent the mounting tab down a bit so as it is tightened it pushes the front of the bracket down/forward. 

      End result is satisfactory though. I would love to come up with a custom gauge bracket somehow that better matched the interior, but I wouldn’t know where to start. 

      150DED70-B323-41C1-B61A-AF4FE6666359.jpeg

      28430912-803C-4B17-8559-2EFB877991A8.jpeg

      I finally got the replacement rear brake line piece. I have the new/correct AC hose in the car and now all of the AC lines are in with new o-rings. Wtih the rear brake lines done I'll be able to put the gas tank back in the car. Once the rear is done I'll move on to the front struts. 

      Debating if I want to rebuild the axles while they are out. From the how-to's I've looked at they appear to be relatively straightforward and all new boots and grease is only $100 to do both axles.

      1 Reply Last reply
      1
      • G
        G
        gilber33
        wrote on last edited by
        #713

        Didn’t realize that the area behind the rear “door” cards are completely bare metal. Took those out and put sound mat in there.

        9F8458C1-568D-4B15-AD39-C103C3256645.jpeg

        Where the gauge relay power and gauge harness comes through the firewall and the runs down to their respective locations. 
         

        FFB9C894-B1F8-40B3-B4DC-37219280372E.jpeg

        87D39918-102E-4856-9A22-279627881A3F.jpeg

        Also discovered that when the power was ran to my garage they ran 220. I asked them to wire the garage for 120v and always assumed they only brought that out to the garage. Cue the installation of 240v outlets. First thing I’m doing is putting in an electric heater. 
         

        68C63D09-4F12-4748-A484-F184986DBE61.jpeg

        1 Reply Last reply
        0
        • straight6pwrS
          straight6pwrS
          straight6pwr
          wrote on last edited by
          #714

          bonus! wish my garage had better electric.

          Dan
          yajsYRL.jpg.e5f350b4dfe961d76ac8b32efce2e1a6.jpg

          1 Reply Last reply
          0
          • HipMFH
            HipMFH
            HipMF
            wrote on last edited by
            #715

            gilber33 said:

            Also discovered that when the power was ran to my garage they ran 220. I asked them to wire the garage for 120v and always assumed they only brought that out to the garage. Cue the installation of 240v outlets. First thing I’m doing is putting in an electric heater. 
             

            68C63D09-4F12-4748-A484-F184986DBE61.jpeg

            Slightly confused what you mean here. 120v single-phase is actually two 120v legs 180 degrees out of phase, so measuring across the two hots give 240v. Measuring hot to neutral will give you 120v. 120v and 240v are both available from the same panel.

            1 Reply Last reply
            0
            • straight6pwrS
              straight6pwrS
              straight6pwr
              wrote on last edited by
              #716

              HipMF said:

              Slightly confused what you mean here. 120v single-phase is actually two 120v legs 180 degrees out of phase, so measuring across the two hots give 240v. Measuring hot to neutral will give you 120v. 120v and 240v are both available from the same panel.

              i'd assume that he means that 240v was run from the main panel to the subpanel. (multiple hot wires on separate breakers, instead of just one)

              Dan
              yajsYRL.jpg.e5f350b4dfe961d76ac8b32efce2e1a6.jpg

              1 Reply Last reply
              0
              • HipMFH
                HipMFH
                HipMF
                wrote on last edited by
                #717

                straight6pwr said:

                i'd assume that he means that 240v was run from the main panel to the subpanel. (multiple hot wires instead of just one)

                Ah that makes sense. I don't think I've ever seen a breaker box that was designed to be powered off of just one leg. I'm pretty sure running all of the available phases to a sub panel is standard practice. It's a bit more efficient in terms of the amount of wire required because current being drawn from the opposing phases cancel each other out, reducing neutral current. ie 2 20 amp circuits only requires one 12ga neutral instead of 2.

                1 Reply Last reply
                0
                • G
                  G
                  gilber33
                  wrote on last edited by
                  #718

                  straight6pwr said:

                  i'd assume that he means that 240v was run from the main panel to the subpanel. (multiple hot wires on separate breakers, instead of just one)

                  This is correct. I meant that they ran a 220a service from the house to the garage's subpanel - two 120v legs to a 2-pole 100a breaker. 

                  Menards has their heaters on sale. Planning on picking one up this week to install that. Roughly estimated that if I use it 3 times a week on its highest setting non-stop for a few hours at a time that it would cost about $30/mo. Which I didn't think is too bad. Beats the noise and smells generated by my current propane torpedo-heater.

                  1 Reply Last reply
                  0
                  • HipMFH
                    HipMFH
                    HipMF
                    wrote on last edited by
                    #719

                    That will be nice. I have a kerosene torpedo heater, and it's handy to have around. It puts out a ton of heat which is nice, but like you said, it's noisy, smelly, and generally a hassle. Not to mention concerns over CO/CO2 when used indoors. Unvented heaters like that also put a ton of moisture in the air which can cause condensation and probably other moisture-related problems.

                    1 Reply Last reply
                    0
                    • G
                      G
                      gilber33
                      wrote on last edited by
                      #720

                      HipMF said:

                      Not to mention concerns over CO/CO2 when used indoors.

                      That is very true. I have a CO alarm in the garage but needed to take the batteries out because it would go off after having the heater going for just a little while.

                      1 Reply Last reply
                      0
                      • GunMetalGreyG
                        GunMetalGreyG
                        GunMetalGrey
                        wrote on last edited by
                        #721

                        gilber33 said:

                        That is very true. I have a CO alarm in the garage but needed to take the batteries out because it would go off after having the heater going for just a little while. 

                        Hahahaha, entirely defeating the point of the alarm. 
                        Not saying I haven't done it, just amusing to read.

                        ...

                        1 Reply Last reply
                        0
                        • G
                          G
                          gilber33
                          wrote on last edited by
                          #722

                          GunMetalGrey said:

                          Hahahaha, entirely defeating the point of the alarm. 
                          Not saying I haven't done it, just amusing to read. 

                          Oh yeah. It served no purpose. Actually, it did serve a purpose. It was telling me to open the doors and get some fresh air.

                          1 Reply Last reply
                          0
                          • jc43089J
                            jc43089J
                            jc43089
                            wrote on last edited by
                            #723

                            Just to clarify, the subpanel having a 100 amp main breaker does not mean 100A is available.  What size is the breaker in the house that feeds it?  It may or may not be 100A the size would depend on the wire gauge that was used.  Either way that is excellent.  If you have wiring questions just ask, I am a master electrician, I'm actually teaching code class to apprentices right now.

                            I have typically run 60A to a garage, so the feeder breaker is a 60A, using 6ga copper wire, and the sub panel is usually 100A rated because that is pretty standard for smaller panels.  There are a couple things to pay attention to in a subpanel.  The ground and neutral wires can't be mixed like in a main panel.  So the grounds need to go to a ground bus attached to the enclosure and the neutrals attach to the neutral bus.  Otherwise you create a parallel circuit and current will flow on the ground wire back to the main panel which is bad/dangerous/against code.

                            Be careful and turn it off when doing anything, don't just turn off the main breaker in the garage panel.  Turn it off at the feeder breaker in the house.  Otherwise the incoming lines are still live and it is easy to slip.

                            2/94 325i Sedan, Arctic Gray: UUC LTW FW, EVO 3 and DSSR, +.020 Maxsil pistons, ASC delete, Eibach shocks/springs, 16" contour reps 238k
                            3/93 325i Coupe, Schwarz 2, Sketchy stance action, ebay turbo, 300k
                            '89 325i Vert, Alpine White: 5spd swapped, sold.

                            '04 Toyota Sienna: 24V to 24V swap in progress

                            '05 Volvo V70R, 6spd.  200k
                            '85 Toyota LandCruiser: Lifted, gas hog. 205k
                            '99 Nissan Maxima: 5spd, Rusty but trusty winter beater. 252k RIP.

                            1 Reply Last reply
                            0
                            • G
                              G
                              gilber33
                              wrote on last edited by
                              #724

                              jc43089 said:

                              Just to clarify, the subpanel having a 100 amp main breaker does not mean 100A is available.  What size is the breaker in the house that feeds it?  It may or may not be 100A the size would depend on the wire gauge that was used.  Either way that is excellent.  If you have wiring questions just ask, I am a master electrician, I'm actually teaching code class to apprentices right now.

                              I have typically run 60A to a garage, so the feeder breaker is a 60A, using 6ga copper wire, and the sub panel is usually 100A rated because that is pretty standard for smaller panels.  There are a couple things to pay attention to in a subpanel.  The ground and neutral wires can't be mixed like in a main panel.  So the grounds need to go to a ground bus attached to the enclosure and the neutrals attach to the neutral bus.  Otherwise you create a parallel circuit and current will flow on the ground wire back to the main panel which is bad/dangerous/against code.

                              Be careful and turn it off when doing anything, don't just turn off the main breaker in the garage panel.  Turn it off at the feeder breaker in the house.  Otherwise the incoming lines are still live and it is easy to slip.

                              I had sent pictures off to a friend of mine who is also an electrician. I believe the breaker for the garage in the main panel is a 60a breaker.

                              F4169697-91EB-4B9B-B6D9-2C3F4D993427.jpeg

                              And thank you, I will! I have some basic, at home DIY knowledge for electrical work - running outlet and a couple lights/switches in our basement. But later this year the garage will be transitioning from a shared garage with my wife to a shop for just me. At that point I'll be building a storage room and an office along the back wall. So I may be back with more electrical questions at that time.

                              1 Reply Last reply
                              0
                              • G
                                G
                                gilber33
                                wrote on last edited by
                                #725

                                It was a relative PITA, mostly my fault, but it’s in and works better than I expected. I have it on the low setting and it raised the temp of the garage 10° in about 45 mins. The garage typically stays 20° warmer than outside and was at 50° when I went inside. 
                                 

                                35CA4B9B-6B4F-4E65-98DA-8DA331140B2F.jpeg

                                1 Reply Last reply
                                1
                                • straight6pwrS
                                  straight6pwrS
                                  straight6pwr
                                  wrote on last edited by
                                  #726

                                  thats hot 

                                  what kind of insulation does your garage have?

                                  Dan
                                  yajsYRL.jpg.e5f350b4dfe961d76ac8b32efce2e1a6.jpg

                                  1 Reply Last reply
                                  0
                                  • G
                                    G
                                    gilber33
                                    wrote on last edited by
                                    #727

                                    straight6pwr said:

                                    thats hot 

                                    what kind of insulation does your garage have? 

                                    Walls and ceiling are both insulated and drywalled . I don’t remember the R value, but it was an average/common one. And the overhead door is insulated.

                                    1 Reply Last reply
                                    1
                                    • G
                                      G
                                      gilber33
                                      wrote on last edited by
                                      #728

                                      Hey guys. I drained the oil last night to work on the gauge senders and my oil has this metal “wave” in it. This is the third time the oil has been drained and maybe 500 miles on the engine rebuild. What are your thoughts on it? Tom recommended cutting the oil filter in half and will do that tomorrow night. I have a magnetic drain plug and it had sole residue on it, but nothing more, maybe less, than my previous cars always had on their drain plugs. 

                                      119B6BA9-095F-4AAC-835F-B4FDB07EEB46.jpeg

                                      1 Reply Last reply
                                      0
                                      • B
                                        B
                                        B C
                                        wrote on last edited by
                                        #729

                                        Option 1:  post this up on www.bobistheoilguy.com and walk away with PTSD

                                        Option 2: use a high quality oil filter and send a sample in to Blackstone during your next oil change.

                                        1 Reply Last reply
                                        0
                                        • G
                                          G
                                          gilber33
                                          wrote on last edited by
                                          #730

                                          B C said:

                                          Option 1:  post this up on www.bobistheoilguy.com and walk away with PTSD

                                          Option 2: use a high quality oil filter and send a sample in to Blackstone during your next oil change.

                                          I've read posts on Bob's forum and I have no interest posting there. lol. 

                                          I was gonig to check the oil this morning to see if the stuff was magnetic or not and it was gone. So I'm wondering if this was some weird froth or something? I don't know. I was freaked out given I just rebuilt the engine and it was my first time. The 20w50 oil in 20-30* is very, very thick, so I couldn't imagine that if it was tiny metal dust that it would have sunk. 

                                          Well, besides the oil, last night I got the coolant and oil filter housing bolt tapped for the senders. The bimmerheads oil pressure sender adapter had the hole tapped on the wrong side. When I screwed it into the block, their port was always facing the block. So I had to drill and tap a hole on the other side and then ordered some 1/8npt plugs. 

                                          6FBFEE3E-22FE-4021-9618-3BB60DB0324E.jpeg

                                          I know the holes are exactly in the middle. I did my best. Get off my back.

                                          1 Reply Last reply
                                          0

                                          Hello! It looks like you're interested in this conversation, but you don't have an account yet.

                                          Getting fed up of having to scroll through the same posts each visit? When you register for an account, you'll always come back to exactly where you were before, and choose to be notified of new replies (either via email, or push notification). You'll also be able to save bookmarks and upvote posts to show your appreciation to other community members.

                                          With your input, this post could be even better 💗

                                          Register Login
                                          Reply
                                          • Reply as topic
                                          Log in to reply
                                          • Oldest to Newest
                                          • Newest to Oldest
                                          • Most Votes


                                          • Login

                                          • Don't have an account? Register

                                          • Login or register to search.
                                          Powered by NodeBB Contributors
                                          • First post
                                            Last post
                                          0
                                          • Categories
                                          • Recent
                                          • Tags
                                          • Popular
                                          • Users
                                          • Groups